Cemtek Instruments offers a complete line of combustion analyzer products and compliance monitoring systems to streamline efficient process control.  All Cemtek instrument's are carefully selected to meet the specific requirements of our customer's application.  Instruments are field tested and fully supported by our team of field service and system engineers.

Document
Cemtek Model 8000 SCR Nox Probe
 
Contact us for product information. Comments:
First Name
Last Name
Company Name
State
Daytime Phone() -
E-mail Address
Document
Cemtek Instruments Application Data Sheet
   

Cemtek's Model 8000 SCR NOx and O2 Monitor has been designed specifically to meet the challenging requirements for monitoring the inlet and outlets of selective catalytic reduction systems on coal fired combustion sources. This can be used for NOx control, NH3 injection control and emissions control.

Designed around a close coupled low flow - low dilution probe, the Model 8000 NOx analyzer integrates all of the major components necessary to simultaneously measure nitric oxide and oxygen concentrations without the need for costly heated sample lines or separate instruments.

Utilizing a  NOx chemiluminescent photo-diode detector,  no photomultiplier tubes, high voltage supply or lamps to fail provides long turn reliability.  Optimization of the NOx reaction cell eliminates the need for temperature, flow and pressure compensation.  Zero drift is practically nonexistent.  An ozone generator that produces ultra clean discharge is also a key feature of the Model 8000 NOx analyzer.

A very compact zironcium oxide sensor with heater and detector cell complete on a momolithic ceramic base requires only 10W of power and is insensitive to ambient temperature swings.  Our sensor uses a proprietary two-stage cell that results in an inherently linear output with excellent sensitivity and stability across it's range.  This results in very low zero drift and no low level calibration gas required.

The Model 8000 NOx analyzer can be mounted directly on a duct port both before and after an SCR to measure real time NOx and O2 or to provide trim control of the ammonia injection process.  An air condition package for applications  is where high ambient temperatures are encountered at the SCR inlet.  The  enclosure/probe is mounted by a 4" ANSI flange.  Simple probe design allows for easy remova and maintenance of filters without the need of removing any other component. 


NOx, NOx control, Chemiluminescent NOx analyzer, NO control, SCR, NOx control, NOx process control and monitoring.


PRODUCT SPECIFICATIONS
                                                                    NOx                                        O2 

Measurement Technology:                    Chemiluminescence                   Zirconium Oxide cell

                                                            Solid state detection
Range (FS adjustable):                         5 to 1000 PPM                            5-25%                           

Linearity (FS):                                      < 2.0%                                       < 1.0%                                                            

Zero Calibration Drift:                          +/- 0.2 PPM                                +/- 0.1 PPM

Zero Noise:                                           <0.02 PPM                                 <0.02% 

Span Calibration Drift:                          +/- 2.0%                                    +/- 0.1%

Span Noise:                                          < 0.25% of reading                      < 0.02% 

Interference (sum of all):                     < 10.0% measured value                < 1.0%                                                

Response Time:                                    < 10 seconds at T95                    < 10 seconds at T95


System Requirements:

Power:                                                                  115VAC, 150 Watts @ 2 A            

Air:                                                                       2 CFM @ 60 PSI

Weight:                                                                 50 lbs approx

Size Dimensions:                                                   22” x 16” x 12” NEMA 4 Enclosure

Outputs:                                                               Isolated 4-20mA per gas measured