Cemtek Instruments offers a complete line of combustion analyzer products and compliance monitoring systems to streamline efficient process control.  All Cemtek instrument's are carefully selected to meet the specific requirements of our customer's application.  Instruments are field tested and fully supported by our team of field service and system engineers.

Document
Model 1010 Data Sheet
 
Contact us for product information. Comments :
First Name
Last Name
Company Name
State
Daytime Phone() -
E-mail Address
Document
Cemtek Instruments Application Data Sheet
   

The Cemtek Model 1010 Oxygen Analyzer provides continuous measurement of oxygen concentrations using Linear Output Zirconium Oxide Technology.  Built within a rugged case, the Model 1010 is ideal for rack mounting in extractive CEMS or for process control in natural gas fired combustion applications.

Utilizing a revolutionary pumped oxygen zirconium oxide cell to measure oxygen concentration, the pumped cell provides truly linear output capable of measuring from 0% to 25% of oxygen without the need for maintaining the 2% oxygen calibration gas normally required for traditional zirconium oxide analyzers.

With its true linear output, full measurement concentration range and ultra stable zero, the Model 1010 is an ideal replacement for paramagnetic technology and standard Zirconium cell.

Available as single or dual channel and fully housed in a low profile (3 inches) 19" rack mount enclosure.


PRODUCT SPECIFICATIONS

Measurement Technology:                          Zirconium oxide (zirconia, ZrO2) cell
Measurement Range:                                  0 to 25% O2
Full Scale Range:                                       Continuously adjustable from 10 to 25% O2
Zero Noise:                                                 Less than 0.02% O2
Zero Calibration Drift:                                Better than ± 0.1% O2
Absolute Accuracy:                                    0.2% or better
Span Noise:                                                Less than 0.2 %O2
Span Calibration Drift:                               Better than ± 0.1% O2
Linearity Error:                                          Less than 1% of high calibration gas value across range
                                                                  from zero to full scale
Interference                                               Less than 1% of measured value
(sum of all interferences):
Response Time:                                          30 seconds max (after warm up)
Voltage:                                                     110VAC operation (approximately 15W)
Weight:                                                      7 lbs