The Model 3000ED is a highly sensitive system consisting of wall or rack mount controller and sample probe/conditioning assembly all integrated into a glass reinforced plastic weather enclosure.  The probe and enclosure mount to the sample port via ANSI flange.

A defined sample flow is extracted from the exhaust gas flow.  The sample is diluted with clean, tempered ambient air and is continuously heated at the probe.  The sample is transported to the measuring cell within the probe enclosure where triboelectric measuring principles are used.  The resultant electrical derived current which is proportional to dust content is scaled as 4-20mA signal and displayed on controller display.


Particulate Monitor
Product Information Model 3000ED

Cemtek Instruments Model 3000ED Particulate Monitor is used for continuous extractive measurement of particulate content in flue-gas exhaust and process monitoring applications.  In addition to particulate concentration, the Model 3000ED simultaneously measures flow and temperature of the flue gas.




Product Highlights

-  Applications including wet, sticky exhaust gases
-  Wall or rack mount controller with separate probe in a glass reinforced plastic weather enclosure
-  Highly sensitive system
-  Simultaneous measurement of particulate, gas velocity and gas temperature
-  Automatic zero and reference calibration


Product Specifications

Control Unit:                Weather-proof aluminium case, dimensions 24 x 12 x 12 inches (W x H x D), 44 lbs,  IP 65 
Probe:                         GRP Weather protection hood 24 x 28 inches, 190 lbs
Ambient Temperature:   -4 to 122 °F
Measuring principle:      Dust via triboelectric sensor  
Measuring range dust:    0 - 15 (max 500) mg/mm³ 
Sample temperature:     32 to 572 °F
Analogue output:           4 - 20 mA dust
Digital outputs:              6 contacts
Power supply:               400 VAC / 50-60Hz
Display:                         4 line LCD



Document
Model 3000ED Application Data Sheet

Also Available

-  Model 3000: Waste Incinerator


Document
Tribolectric Principle of Operation